Validation of SpO/FiO as a Non-Invasive Surrogate of PaO/FiO in Mechanically Ventilated COVID-19 Patients at High Altitude.

Publication date: Apr 28, 2026

The ratio of arterial partial pressure of oxygen to fraction of inspired oxygen (PaO/FiO) is central to the classification of acute respiratory distress syndrome (ARDS). However, its assessment requires arterial blood gas analysis, which may be limited by availability, cost, and invasiveness. Consequently, the ratio of peripheral oxygen saturation to fraction of inspired oxygen (SpO/FiO) has been proposed as a non-invasive surrogate for estimating the degree of oxygenation impairment. A retrospective cross-sectional study was conducted in adult patients with COVID-19 admitted to the intensive care unit at an altitude of 2600 m above sea level (m. a.s. l.). Spearman correlation coefficients were calculated to assess the association between the SpO/FiO and PaO/FiO ratios and their corresponding imputation models. A generalized linear model was applied, and the diagnostic performance of the SpO/FiO ratio and the imputation models for detecting severe and non-severe hypoxemia (PaO/FiO cutoff value of 150) was evaluated using the area under the receiver operating characteristic curve (AUC). A total of 473 patients receiving invasive mechanical ventilation were included, with a mean age of 62. 4 years (SD 14. 1), and a predominance of males (67. 2%). An SpO/FiO ratio cutoff value of ≥206 demonstrated excellent diagnostic performance, with an AUC of 0. 983 (95% CI 0. 97-0. 99), high sensitivity (90. 6%), high specificity (96. 7%), and an overall correct classification rate of 93. 9%. This performance remained consistent across multiple clinical scenarios. In patients with positive end-expiratory pressure > 10 cmHO, the AUC was 0. 982, with a specificity of 97. 7%. In the presence of hyperbilirubinemia (total bilirubin ≥ 3 mg/dL), the AUC was 0. 951. Among patients with hemoglobin levels 35 mmHg, an SpO/FiO ratio ≥ 206 showed near-perfect specificity (99. 4%) and a positive likelihood ratio of 120. 9. The SpO/FiO ratio is a reliable and non-invasive surrogate of the PaO/FiO ratio in mechanically ventilated patients with COVID-19 living at high altitude, particularly for the identification of non-severe hypoxemia.

Open Access PDF

Concepts Keywords
Hemoglobin Aged
Hyperbilirubinemia Altitude
Models Biomarkers
Spearman Biomarkers
Blood Gas Analysis
COVID-19
COVID-19
Cross-Sectional Studies
Female
Humans
hypoxemia
Hypoxia
Intensive Care Units
Male
Middle Aged
oximetry
Oxygen
Oxygen
Oxygen Saturation
Pandemics
Partial Pressure
pulse oximetry
Respiration, Artificial
Respiratory Distress Syndrome
respiratory distress syndrome
Retrospective Studies
SARS-CoV-2

Semantics

Type Source Name
disease MESH COVID-19
drug DRUGBANK Oxygen
disease MESH acute respiratory distress syndrome
disease MESH hypoxemia
disease MESH included
disease MESH hyperbilirubinemia
drug DRUGBANK Carbon dioxide
drug DRUGBANK Coenzyme M
disease MESH hypercapnia
disease MESH anemia
disease MESH critically ill
disease MESH syndrome
disease MESH lung injury

Original Article

(Visited 6 times, 1 visits today)

Leave a Comment

Your email address will not be published. Required fields are marked *