Publication date: Jun 23, 2026
Background: The continued evolution of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) created ongoing challenges for molecular diagnostics and variant surveillance. Assays capable of maintaining diagnostic sensitivity across emerging variants while providing variant-related information remain essential for clinical and public health applications. This study evaluated the performance of the GXT96 X3 extraction kit in combination with the FluoroType SARS-CoV-2 varID Q version 1. 0 assay (Hain LifeScience SA (Pty) Ltd. , South Africa) for the detection, semi-quantitative assessment, and variant characterization of SARS-CoV-2 under laboratory conditions. Methods: A total of 220 samples were evaluated, including residual nasopharyngeal clinical specimens (n = 183), reference materials, and cultured SARS-CoV-2 virus dilutions. Residual specimens collected during multiple COVID-19 waves in South Africa (wild-type, Beta, Delta, and Omicron) were compared against standard-of-care (SOC) molecular assays used for routine diagnosis. RNA extraction was performed using the automated GXT96 X3 platform, followed by amplification on the FluoroCycler XT using the FluoroType SARS-CoV-2 varID Q assay targeting RdRp and N genes, with additional spike gene mutation detection for variant detection. Diagnostic accuracy, agreement (Cohen’s kappa), precision, linearity, and limit of detection (LoD) were assessed. Results: The assay demonstrated a sensitivity of 98. 4% (95% CI: 94. 2-99. 8) and specificity of 100% (95% CI: 95. 9-100. 0) compared with SOC assays, with an overall agreement of _705 = 0. 981. Precision analysis showed acceptable reproducibility with a standard deviation of ≤1. 49 and a coefficient of variation of ≤3. 83%. Regression analysis demonstrated linearity across the dilution series (R = 0. 9882 for RdRp and 0. 994 for N genes). The LoD was ≤100 copies/mL for the RdRp gene and 250 copies/mL for the N gene. Variant-associated spike mutations corresponded broadly with epidemiological wave patterns observed in South Africa. Conclusions: Under the evaluated laboratory conditions, the GXT96 X3 extraction platform combined with the FluoroType SARS-CoV-2 varID Q assay demonstrated high diagnostic accuracy and reproducibility for SARS-CoV-2 detection across a range of viral loads with additional spike gene mutation detection as an adjunct feature.
| Concepts | Keywords |
|---|---|
| diagnostic performance evaluation | |
| molecular diagnostics | |
| RT-PCR detection | |
| SARS-CoV-2 | |
| variant mutation |
Semantics
| Type | Source | Name |
|---|---|---|
| disease | MESH | severe acute respiratory syndrome |
| disease | MESH | COVID-19 |